Technologies

** Click the topic to see additional details, in the format of “.pdf”

1. Carbon Fiber (CF)
Technology for strengthening of the structure by means of composite materials

 

2. Impressed Current Cathodic Protection (ICCP)
Under this system, steel reinforcement inside the concrete structure will be provided with electron from an external source, by feeding low voltage DC current, which will prevent the steel from losing its own electron (real cause of corrosion and rusting of the steel). If design and installation were done properly and correctly, the system will completely 100% protect the steel from rusting and corrosion. Level of the current can be adjusted to suit with severity in corrosion and rusting of the steel.

 

3. Thermally Arc-Sprayed Alloy CP System (TASAS)
Under this system, melted special alloy (or zinc) will be sprayed on surface of the concrete or steel ( for steel structures). The steel or steel reinforcement will obtain electron directly from the special alloy ( or zinc) sprayed atop. As result, steel will not get corroded or rusting due to losing of its own electron. In severe corrosion environment, the special alloy will be preferable over zinc due to its higher rate in supplying electron.



4. Smart Load Alarm System (SLAS)
Technology for monitoring of the structure and warning on strange or improper structural behaviors to allow for the proper action being taken beforehand.